EthMBus-XL SMART

models 20, 45, 80, 120, 190

Ethernet to M-Bus communication converter

Converter for SMART metering

Designed for remote communication with M-Bus meters using the Ethernet computer network in industry, building automation.

In the Smart M-Bus mode the converter works as a server. It communicates with the M-Bus meters independently, processes their data and stores it in its own memory. The meter data is simultaneously available in form of:

  • table on a webpage
  • xml, xml(REST) and csv export
  • M-Bus protocol communication
  • e-mail with attached xml, csv exports
  • exports uploaded to an FTP server

Document with detailed functionality description.

In the basic mode the converter works as a transparent gateway for transfer of M-Bus messages using TCP or UDP Ethernet protocols.

Notice: The Smart M-Bus mode for converter models XL120 and XL190 is limited to 92 addresses for M-Bus slave devices in the current version of firmware (Feb 2026 and newer).

Changes in firmware

The latest version of firmware adds important improvements and better functionality to existing features.
The list of changes is available in this file.

Main characteristics

The M-Bus converter features a processor controlled monitoring of internal state, power supply state and M-Bus line state. Operation and error states are indicated by status LEDs which simplify and make it easier to troubleshoot possible M-Bus communication errors.

M-Bus port
  • Connection of 1 to 20, 45, 80, 120 or 190 M-Bus slave devices depending on converter model.
    The most commonly used devices are heat, water, gas and electricity consumption meters.
  • Surge protection warranting above standard level of protection against overvoltage.
  • Current protection against overload and short circuit on the communication line.
  • External voltage protection.
  • Processor controlled monitoring of M-Bus line state with LED indication for various error states.
  • Indication of M-Bus slave devices reply collision.
  • Indication of slave devices presence on the M-Bus line.
  • Indication of M-Bus line overload, short and capacitive overload.
Power supply
  • Wide range of operating DC power supply voltages 12-30V (20-30V for the XL190 model).
  • Overvoltage protection.
  • Processor controlled monitoring of power supply voltage with indication of its correctness and errors.
Ethernet
  • TCP, UDP protocols and virtual COM port software.
  • 10/100BASE-TX ethernet port, RJ45 connector.
Mechanical construction
  • Aluminium box with mounting on 35 mm DIN rail.

Main software characteristics

Transparent gateway mode:
  • TCP/IP connection
    • server or client mode
    • backup IP addresses for connection
    • connection to a web address (DNS)
  • UDP connection
Smart M-Bus application mode:
  • web page with meter data
  • xml, xml(REST), csv exports
  • e-mails with exports and service information
  • exports uploaded to an FTP server
Software functions
  • Configuration of the converter through a web interface or Telnet.
  • TCP and UDP communication in server or client mode including connection backup IP addresses.
  • DNS support (host name instead of IP)
  • Logging of Ethernet activity and error states.
  • Search for meter addresses and their change (meter must support this functionality).
  • Success rate statistics for communication with individual meters.

Guarantee of quality

  • Each converter passes through several functional electrical tests during the production.
  • Additionally a communication test is performed after final assembly.
  • EMC certification in an accredited laboratory for industrial environment.
  • Solid design and construction based on many years practical experience.
Ethernet communications interface
Communications interface 10BASE-T or 100BASE-TX (auto-sensing)
Communication protocols ARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, SNMP
Connector RJ45
Compatibility Ethernet: Version 2.0/IEEE 802.3
M-Bus Master communication interface
Number of attachable devices – XL20 1 to 20 SLAVE devices, idle current max. 30mA
Number of attachable devices – XL45 1 to 45 SLAVE devices, idle current max. 67.5mA
Number of attachable devices – XL80 1 to 80 SLAVE devices, idle current max. 120mA
Number of attachable devices – XL120 1 to 120 SLAVE devices, idle current max. 180mA
Number of attachable devices – XL190 1 to 190 SLAVE devices, idle current max. 285mA
Baud rate 300 – 9600 bps
Protection – overvoltage protection TVS 1500W
– electronic protection against external voltage
– electronic protection against overloads and short circuit on the communication line
note: converter can withstand sustained short circuit on the communication line
Galvanic separation up to 1kV from power supply, more than 1kV from Ethernet
Connector terminal block with plug-in connector for wires of up to 2.5 mm2 cross-section area
Power supply
Recommended range of power supply voltages
DC power supply 12V to 30V, model XL190 20V to 30V
Maximum limits of supply voltage – permanent operation at these voltages is not recommended
Minimum DC voltage 11V – min. voltage required for converter operation
Maximum DC voltage 31V – at higher the overvoltage protection starts to activate
Protection – overvoltage protection TVS 1500W
– power supply polarity reversal protection
Power consumption 1.8W to 16W depends on converter model and number of M-Bus devices
Connector terminal block with plug-in connector for wires of up to 2.5 mm2 cross-section area
Status LEDs
Power – green power indication. Indicates a converter malfunction when flashing.
Transmit – green indication of data transmission on the M-Bus line
Receive – yellow indication of data reception on the M-Bus line
Meters – yellow indication of M-Bus meters on the line
Err./Coll. – red indication of error, overload, collision on the M-Bus line
Note: For further details on LED indication see manual.
Temperature
Operating range -40°C to 60°C
Mechanical construction
Mechanical design aluminium box
Mounting 35 mm DIN rail (EN 50022 top hat rail)
Dimensions: height x width x length 38 x 81.5 x 107 mm – without connectors
38 x 81.5 x 125 mm – with connectors
Protection classification IP40
Weight 230g (XL20, XL45, XL80) 250g (XL120, XL190)

EMC compatibility of the M-Bus converter has been tested according to the following industrial environment standards.

EMC emission tests
Standard Test Level
EN 55011 Power line – CONDUCTED EMISSIONS 10/150 kHz – 30 MHz Class A
EN 55011 RADIATED EMISSIONS (Electric Field) 30 MHz – 1000 MHz Class A
EMC immunity tests
Standard Test Level
EN 61000-4-2 ELECTROSTATIC DISCHARGE (ESD) – Contact discharge ± 4 kV
EN 61000-4-2 ELECTROSTATIC DISCHARGE (ESD) – Air discharge ± 8 kV
EN 61000-4-3 RADIATED RADIO-FREQUENCY ELECTROMAG. FIELD 80MHz – 1GHz 10 V/m
EN 61000-4-3 RADIATED RADIO-FREQUENCY ELECTROMAG. FIELD 1.4GHz – 2GHz 10 V/m
EN 61000-4-3 RADIATED RADIO-FREQUENCY ELECTROMAG. FIELD 2GHz – 2.7GHz 3 V/m
EN 61000-4-4 ELECTRICAL FAST TRANSIENT/BURST – Power line ± 4 kV
EN 61000-4-4 ELECTRICAL FAST TRANSIENT/BURST – M-Bus line ± 4 kV
EN 61000-4-5 SURGE IMMUNITY – Power line. Common/differential mode. ± 1 kV / ± 500 V
EN 61000-4-5 SURGE IMMUNITY – M-Bus line. Cable shielding. ± 4 kV
EN 61000-4-5 SURGE IMMUNITY – M-Bus line. Common/differential mode.* ± 4 kV / ± 2 kV
EN 61000-4-6 CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY
FIELDS 0.15MHz – 80 MHZ. M-Bus line.
10 V

* test carried out at the request of the manufacturer. The M-Bus port has an increased durability against overvoltage. Carrying out this type of test is not required with the use of shield cable.

End user

Price list for individuals and companies which do not buy converters for resale.

Pricelist

Integrator

Price list for companies which buy converters for the purpose of resale to their custommers as manufacturers or suppliers.

Pricelist (registered business partners)

The price list is available only to registered business partners.
Registration request.

Registration

Leaflet

Name / File
Date
Size
Promotional leaflet
EthMBus-XL_SMART_flyer_v1_8_EN.pdf
Date:
23.2. 2026
Size:
628 kB

Manuals

Name / File
Date
Size
Short overview of modes and functions
Ethernet_SMART_features_flyer_v0_13_EN.pdf
Date:
19.10. 2016
Size:
640 kB
Manual
EthMBus-XL_SMART_manual_v1_6_EN.pdf
Date:
23.2. 2026
Size:
1.47 MB
Web Interface manual
Ethernet_SMART_Web_Interface_v0_53_EN.pdf
Date:
23. 2. 2026
Size:
2,30 MB
Telnet Setup manual
Ethernet_SMART_Telnet_v1_30_EN.pdf
Date:
23. 2. 2026
Size:
1,25 MB
Data exports manual
Ethernet_SMART_exports_v1_06_EN.pdf
Date:
23. 2. 2026
Size:
1,09 MB

Readout software

Name / File
Date
Size
Excel® file for M-Bus data collection and processing
JC-E_readout_v11_6_EN.xlsm
Date:
16. 3. 2018
Size:
228 kB
Manual for the data collecting Excel® file
JC-E_readout_xls_manual_v1_12_EN.pdf
Date:
11.1. 2023
Size:
2.13 MB

Lantronix utilities

Name / File
SW application from Lantronix for advanced configuration of the converters
https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/106070471/Latest+version+of+DeviceInstaller
SW application for creating a virtual COM port from Lantronix
http://www.lantronix.com/device-networking/utilities-tools/com-port-redirector.html

Warning: Lantronix Com Port Redirector doesn’t work with LITE converters. Those use a different application to provide this type of functionality.

Pohľad zhora

späť ↑

Doporučené zapojenie

Doporučené zapojenie prevodníka s M-Bus zariadeniami, napájacím zdrojom a pripojením k počítaču prostredníctvom siete Ethernet.

späť ↑

LED indikácia

Indikácia prevádzkových stavov

Indikačné LED diódy Stav
Power LED svieti Prevodník a napájanie je v poriadku.
Transmit LED bliká Sú vysielané dáta na M-Bus linku.
Receive LED bliká Sú prijímané dáta z M-Bus linky.
Svieti Meters LED Zaťažená M-Bus linka. Na linku sú pripojené merače.
Nesvieti Meters LED Odpojená M-Bus linka. Na linku nie sú pripojené merače.
Rýchlo bliká Meters LED Dosiahnutá max. kapacita meračov na M-Bus linke (tolerancia 2 meračov).

Indikácia poruchových stavov

Indikačné LED diódy Stav
Power LED bliká Interná chyba prevodníka.
Power LED bliká + svieti Err./Coll. LED Cudzie napätie na M-Bus linke, alebo interná chyba prevodníka.
Err./Coll. LED bliká, alebo svieti Preťažený prevodník – príliš veľa meračov, skrat na M-Bus linke, alebo kapacitne preťažená M-Bus linka (C linky > 5μF).
Pri zapnutí napájania – kapacitne preťažená M-Bus linka (C linky > 1μF). Zvýšenú kapacitu môžu spôsobovať M-Bus merače pri zapnutí. Kapacita môže potom klesnúť pod 1μF.
Na krátko zasvieti Err./Coll. LED Pri príjme dát – bliká Receive LED. Komunikačná kolízia. Súčasné odpovedanie viacerých meračov.
Pri vysielaní dát – bliká Transmit LED. Dochádza k chybe pri vysielaní (chybné napätia na M-Bus linke). Interná chyba prevodníka, alebo kapacitné preťaženie M-Bus linky.

späť ↑

Konektory časť M-Bus

Konektor Typ
M-Bus Konektor pre pripojenie M-Bus linky. SH-02-5,08

späť ↑

Konektory časť napájania a Ethernetu

Konektory Typ
Power Konektor pre pripojenie napájacieho napätia. SH-02-5,08
V+ Kladný pól jednosmerného napájacieho napätia.
V- Záporný pól jednosmerného napájacieho napätia.
Uzemnenie.
Ethernet RJ45 Konektor pre pripojenie Ethernetového kábla. RJ45
Indikačné LED diódy Farba
Link Rýchlosť pripojenia 10Mbps oranžová
Rýchlosť pripojenia 100Mbps zelená
Rx/Tx Half-duplex oranžová
Full-duplex zelená

späť ↑

Web interface

späť ↑

Tabuľka M-Bus meračov

späť ↑

Rozmery

späť ↑